Pre-configured System
Atlas HD Crystallization
Allows crystallization processes to be monitored and controlled, as well as performing sonocrystallization or sonomilling techniques.
Applications
This product is suitable for the following applications.
At a glance
The Atlas HD Crystallization system allows turbidity to be monitored and modified by controlling temperature and/or additions to the vessel. Real-time data is displayed on the Atlas HD touch screen and can be plotted in real time using the software.
The proprietary ultrasound technology with novel transducer based design, allows reproducible control of crystallizations, enabling selectivity of parameters such as particle size, shape, crystallinity, and polymorphism.
Monitor your crystallization using the Atlas turbidity probe and node and control the process using the innovative SonoLab module to perform sonocrystallization or sonomilling techniques.
- Real-time data displayed & plotted on Atlas HD touch screen
- Reproducible control of crystallizations
Dimensions
Smallest vessel: | 108cm H x 54cm W x 45cm D |
Largest vessel: | 115cm H x 58cm W x 45cm D |
Power: | 100-240 VAC, 50/60 Hz, 5A Fuse |
1. Controlled crystallization using sonocrystallization techniques
Sonocrystallization is the application of high intensity, low frequency ultrasound to your process, resulting in acoustic cavitation of the solution. Controlled cavitation allows extremely accurate control of nucleation, a process which is random and very difficult to control by conventional techniques. The Atlas HD Crystallization system combines the powerful Atlas HD Potassium with a proprietary ultrasonic flow cell, generator and recirculating pump which can help you control the nucleation and growth of your crystallization process.
2. Exact control of cooling and anti-solvent crystallization
The system can provide excellent control whether performing controlled cooling or anti-solvent crystallization. Either using the base unit or PC software, the system contains sophisticated algorithms for precise temperature control ensuring that the process can be maintained within the metastable zone. Anti-solvent crystallization is performed using the Atlas syringe pump which offers precise dosing from 1 μL/min to 10 mL/min.
3. Unrivalled automation
The Atlas HD Crystallization system has an intuitive touch screen control base, delivering unmatched capability to define and monitor proces conditions over a broad range of working volumes. The touch screen allows you to change parameters such as stirring, heating and dosing in real time and displays all data in a graphical way. Further automation can be provided using PC software for complete crystallization control.
4. Narrow particle size distribution
Initiating nucleation using ultrasound offers reproducible crystallization. The crystal growth can also be controlled with ultrasonic energy providing a very uniform and narrow particle size distribution. Once crystals are formed, the system is in sonomilling mode and varying the intensity of the ultrasound, allows you to tailor the particle to your desired size. Third party particle size monitors can also be integrated into the Atlas HD system ensuring that the platform provides all you need to master your crystallization
Specifications
Vessel Volume Range | 50 mL, 100 mL, 250 mL, 500 mL, 1 L, 2 L (DN80), 1 L, 2 L, and 5 L (DN150) |
---|---|
Vessel Shapes | Torispherical, Conical, Round Bottom |
Vessel Profiles | Jacketed, Vacuum Jacketed |
Other Vessel Types | No (Round Bottom Flasks Available with Regular Atlas Base) |
Temperature Range | -90°C to 250°C (with suitable seal kit) |
Stirring Options | Scorpion Overhead Stirrer (up to 800rpm/11Ncm torque), High Speed Available, High Torque Available |
Automation | Yes – using Atlas PC Software |
Modes of Operation | Atlas HD Touch Screen Control, Atlas PC Software, Manual Operation |
Sensor Options | Temperature, pH, Pressure, Turbidity, In-situ FTIR, Other Sensors Available |
Pressure Range | Vacuum (50mbar) to 0.5 Bar, See Atlas 200 Bar Pressure Systems for High Pressure up to 200 Bar, See Atlas 3 Bar Pressure Systems for High Pressure up to 3 Bar |
Reaction Calorimetry | Ability to Upgrade to Reaction Calorimetry, See Atlas HD Calorimeter |
Reagent Addition and Sampling | Manual Dosing, Automated Dosing (Volumetric), Automated Dosing (Gravimetric), Sampling of Liquids, Full Gas Control, Atlas Syringe Pump Range |
Modules
-
Base units
-
Atlas HD Potassium
The Atlas HD Potassium is the base reactor system on which all Atlas HD systems are built, and can be […]
View module details
-
-
Probes and Nodes
-
Turbidity Probe and Node
Accurate measurement and monitoring of turbidity in partnership with the Atlas HD base. Turbidity Probe The Turbidity Probe can be […]
View module details
-
-
Advanced Applications
-
Prosonix Sonolab SL10 Sonocrystallizer (230V/110V)
The Prosonix Sonolab is a high-performance ultrasound module allowing full control of crystallization processes, for use with the Atlas HD […]
View module details -
Sonocrystallizer Accessories Pack
The Sonocrystallizer Accessories Pack contains a peristaltic pump, tubing, connectors, and valves for recycling the reactor contents through the Sonolab […]
View module details
-
-
Circulation
-
Circulator and Fluid
Circulator options from industry-leading manufacturer, Huber. A range of circulator accessories and oils for whatever your application are available.
View module details
-
-
Dosing
-
Atlas Syringe Pump
A perfect addition to your lab, the Atlas Syringe Pump and Atlas XL Syringe Pump can be used as standalone syringe […]
View module details
-
-
Optional modules
-
Atlas Syringe Pump
A perfect addition to your lab, the Atlas Syringe Pump and Atlas XL Syringe Pump can be used as standalone syringe […]
View module details -
Circulator and Fluid
Circulator options from industry-leading manufacturer, Huber. A range of circulator accessories and oils for whatever your application are available.
View module details
-
Support
These support articles may be helpful for this system